Magnetomotive Force
Magnetomotive Force
   mmf = 0.4ΠNI
   mmf = 0.4πNI
   N: number of turns
   N: number of turns
   I: current
   I: current
Magnetizing Force
  H = mmf / MPL
  MPL: magnetic path length
Flux Density
  B =μH
  μ: permeability of core
[[Category:Electronics]]
[[Category:Electronics]]
[[Category:Notes]]
[[Category:Notes]]

Revision as of 16:03, 29 August 2018

Magnetics covers transformers and inductors

Transformer

These are just a pain to understand

Larger transformers increase hysteresis loss.

The correct frequency is critical. Ideally, the frequency should be as low as possible without saturating the transformer. Higher frequency increases hysteresis loss.

Materials

  • Laminated Iron Alloyws: 1.5-2.0T 50Hz-1KHz
  • Powdered Iron: 0.6-0.8T 1KHz - 100KHz
  • Ferrites: 0.25-0.5T 20KHz - 20MHz

Higher tesla is associated with higher core losses, but also higher saturation.

DIY Tests

  • epoxy and magnetite
  • epoxy and ferrite (Fe2O3)
  • laminated steel plates
  • plaster as binder

If I had access to a kiln I could try making soft ferrites by mixing Fe2O3 and ZnO and heating to 1500F.

Notes from "Transformer and Inductor Design Handbook"

1

Hysteresis produces core loss.

Two forces; magnetomotive force (mmf) and magnetizing force (H).

Units

  • Magnetomotive: Gilberts
  • Magnetizing: Gilberts/cm = Oersteds
  • Flux Density: Gauss

Magnetomotive Force

 mmf = 0.4πNI
 N: number of turns
 I: current

Magnetizing Force

 H = mmf / MPL
 MPL: magnetic path length

Flux Density

 B =μH
 μ: permeability of core